Fracture resistance of CAD/CAM endocrowns bonded by different bonding
5 Angebote vergleichen

Bester Preis: Fr. 47.51 ( 48.61)¹ (vom 01.06.2018)
1
9783330650817 - Israa Kassem: Fracture resistance of CAD/CAM endocrowns bonded by different bonding
Symbolbild
Israa Kassem

Fracture resistance of CAD/CAM endocrowns bonded by different bonding (2018)

Lieferung erfolgt aus/von: Deutschland DE PB NW

ISBN: 9783330650817 bzw. 3330650818, in Deutsch, 124 Seiten, SPS, Taschenbuch, neu.

Fr. 58.55 ( 59.90)¹
versandkostenfrei, unverbindlich
Lieferung aus: Deutschland, Versandkosten nach: Deutschland, Versandkostenfrei.
Von Händler/Antiquariat, Buchhandlung - Bides GbR, [4124740].
Neuware - Objectives: The purpose of this study was to evaluate the fracture resistance of two CAD/CAM endocrown materials using two bonding protocol self-etch and total etch. Materials and Methods: 32 endodontically treated teeth were prepared divided into two main groups Group 1: Ceramill endocrowns (n=16) and Group 2: Cerasmart endocrowns (n=16) and subgrouped (n=8) according to the bonding protocol into total etch and self-etch and bonded using RelyX Ultimate. All samples were subjected thermomechanical aging using chewing simulator to resemble 1 year of intraoral function, then fracture resistance was tested using instron testing machine. Results: results were analyzed using two-way ANOVA for comparing material group type and cementation approach effect on different variable studied. Chi square test was performed between fracture patterns. The Ceramill comp endocrowns recorded higher mean fracture resistance (2420.178553.3 N) than the Cerasmart endocrowns However, the difference was insignificant(p 0.5). 15.05.2018, Taschenbuch, Neuware, 220x150x7 mm, 201g, 124, Internationaler Versand, offene Rechnung (Vorkasse vorbehalten), PayPal, Banküberweisung.
2
9783330650817 - Israa Kassem: Fracture resistance of CAD/CAM endocrowns bonded by different bonding
Symbolbild
Israa Kassem

Fracture resistance of CAD/CAM endocrowns bonded by different bonding (2018)

Lieferung erfolgt aus/von: Deutschland DE PB NW

ISBN: 9783330650817 bzw. 3330650818, in Deutsch, SPS Mai 2018, Taschenbuch, neu.

Fr. 58.55 ( 59.90)¹
versandkostenfrei, unverbindlich
Lieferung aus: Deutschland, Versandkostenfrei.
Von Händler/Antiquariat, AHA-BUCH GmbH [51283250], Einbeck, Germany.
Neuware - Objectives: The purpose of this study was to evaluate the fracture resistance of two CAD/CAM endocrown materials using two bonding protocol; self-etch and total etch. Materials and Methods: 32 endodontically treated teeth were prepared divided into two main groups; Group 1: Ceramill endocrowns (n=16) and Group 2: Cerasmart endocrowns (n=16) and subgrouped (n=8) according to the bonding protocol into total etch and self-etch and bonded using RelyX Ultimate. All samples were subjected thermomechanical aging using chewing simulator to resemble 1 year of intraoral function, then fracture resistance was tested using instron testing machine. Results: results were analyzed using two-way ANOVA for comparing material group type and cementation approach effect on different variable studied. Chi square test was performed between fracture patterns. The Ceramill comp endocrowns recorded higher mean fracture resistance (2420.178±553.3 N) than the Cerasmart endocrowns; However, the difference was insignificant(p 0.5). 124 pp. Englisch, Books.
3
9783330650817 - Fracture resistance of CAD/CAM endocrowns bonded by different bonding

Fracture resistance of CAD/CAM endocrowns bonded by different bonding

Lieferung erfolgt aus/von: Schweiz DE NW

ISBN: 9783330650817 bzw. 3330650818, in Deutsch, neu.

Fr. 56.05
unverbindlich
Lieferung aus: Schweiz, Lieferzeit: 11 Tage.
Objectives: The purpose of this study was to evaluate the fracture resistance of two CAD/CAM endocrown materials using two bonding protocol, self-etch and total etch. Materials and Methods: 32 endodontically treated teeth were prepared divided into two main groups, Group 1: Ceramill endocrowns (n=16) and Group 2: Cerasmart endocrowns (n=16) and subgrouped (n=8) according to the bonding protocol into total etch and self-etch and bonded using RelyX Ultimate. All samples were subjected thermomechanical aging using chewing simulator to resemble 1 year of intraoral function, then fracture resistance was tested using instron testing machine. Results: results were analyzed using two-way ANOVA for comparing material group type and cementation approach effect on different variable studied. Chi square test was performed between fracture patterns. The Ceramill comp endocrowns recorded higher mean fracture resistance (2420.178±553.3 N) than the Cerasmart endocrowns, However, the difference was insignificant(p 0.5).
4
9783330650817 - Kassem, Israa: Fracture resistance of CAD/CAM endocrowns bonded by different bonding
Symbolbild
Kassem, Israa

Fracture resistance of CAD/CAM endocrowns bonded by different bonding

Lieferung erfolgt aus/von: Deutschland DE PB NW

ISBN: 9783330650817 bzw. 3330650818, in Deutsch, Taschenbuch, neu.

Fr. 53.58 ( 54.82)¹
versandkostenfrei, unverbindlich
Lieferung aus: Deutschland, Versandkostenfrei.
Von Händler/Antiquariat, European-Media-Service Mannheim [1048135], Mannheim, Germany.
Publisher/Verlag: Scholar's Press | Objectives: The purpose of this study was to evaluate the fracture resistance of two CAD/CAM endocrown materials using two bonding protocol; self-etch and total etch. Materials and Methods: 32 endodontically treated teeth were prepared divided into two main groups; Group 1: Ceramill endocrowns (n=16) and Group 2: Cerasmart endocrowns (n=16) and subgrouped (n=8) according to the bonding protocol into total etch and self-etch and bonded using RelyX Ultimate. All samples were subjected thermomechanical aging using chewing simulator to resemble 1 year of intraoral function, then fracture resistance was tested using instron testing machine. Results: results were analyzed using two-way ANOVA for comparing material group type and cementation approach effect on different variable studied. Chi square test was performed between fracture patterns. The Ceramill comp endocrowns recorded higher mean fracture resistance (2420.178±553.3 N) than the Cerasmart endocrowns; However, the difference was insignificant(p 0.5). | Format: Paperback | Language/Sprache: english | 124 pp.
5
9783330650817 - Israa Kassem: Fracture resistance of CAD/CAM endocrowns bonded by different bonding
Symbolbild
Israa Kassem

Fracture resistance of CAD/CAM endocrowns bonded by different bonding (2018)

Lieferung erfolgt aus/von: Deutschland EN PB NW

ISBN: 9783330650817 bzw. 3330650818, in Englisch, 124 Seiten, Sps, Taschenbuch, neu.

Fr. 52.32 ( 53.53)¹
versandkostenfrei, unverbindlich
Lieferung aus: Deutschland, Gewöhnlich versandfertig in 24 Stunden, Versandkostenfrei. Tatsächliche Versandkosten können abweichen.
Von Händler/Antiquariat, averdo24.
Taschenbuch, Label: Sps, Sps, Produktgruppe: Book, Publiziert: 2018-05-15, Studio: Sps.
Lade…